03119 rev. 07
Installer Manual
VENTILATION SYSTEMS
vänEE Canadian Model Numbers
1001 ERV
1001 HRV
2001 ERV
2001 HRV*
Broan U.S.A. Model Numbers
HRV100H
HRV200H
ERV100HC
ERV200HC
VB0065
* This product earned the ENERGY STAR
®
by
meeting strict energy efficiency guidelines set
by Natural Resources Canada and the US
EPA. It meets ENERGY STAR requirements
only when used in Canada.
Vedere la pagina 0
1 2 3 4 5 6 ... 27 28

Sommario

Pagina 1 - Installer Manual

03119 rev. 07Installer ManualVENTILATION SYSTEMSvänEE Canadian Model Numbers1001 ERV1001 HRV2001 ERV2001 HRV*Broan U.S.A. Model NumbersHRV100HHRV200HE

Pagina 2 - Table of Contents

105. Installation (cont’d)Use the table below to ensure that the ducts you intend to install will be carrying air flows at or under the recommended va

Pagina 3 - 1. Service

There are two methods for connecting the unit to the furnace:Method 1: Supply side connection• Cut an opening into the furnace supply duct at least 18

Pagina 4 - 1. Service (cont’d)

125. Installation (cont’d)5.4.3 Simplified installation (Volume Ventilation) (as illustrated in Section 4.3)There are two methods (figures 12 and 13)

Pagina 5 - ZONE C SELECTION CHART

Insulated flexible ductUse the following procedure for connecting the insulated flexible duct to the ports on the unit (exhaust to outside and fresh a

Pagina 6 - 3. Technical Data

Make a water trap loop in the tubeto prevent the unit from drawingunpleasant odors from the drainsource. Make sure this loop is locatedBELOW the “T” a

Pagina 7 - 3. Technical Data (cont’d)

15VT1W model(U.S.A.)6.1 MAIN CONTROLS6. Control DevicesCONDENSATION CONTROLAIR SUPPLY CONTROLMIN.MAX.OFFAIREXCHANGE-20°C-4° F-5° C23°F5°C41°FCOMFORTZO

Pagina 8 - 4. Typical Installation

6.4 MAIN AND OPTIONAL CONTROLS AVAILABLE FOR YOUR UNIT6.3 OTHER FEATURESFURNACE INTERLOCK (for forced air heating system)The furnace fan can be interl

Pagina 9 - Figure 7

7.2 INSTALLATION OF THE MAIN CONTROL7. Installation of the Controls7.1 DIMENSIONS AND SPECIFICATIONS (MAIN CONTROLS)5" (127 mm)VC0016A5" (12

Pagina 10 - 5. Installation (cont’d)

7.2 INSTALLATION OF THE MAIN CONTROL (CONT’D)187.2.3 Dehumidistat, DH100W, VT1W, and VT2W Main Controls Installation1- Determine the location of the c

Pagina 11 - Figure 11

197.3 ELECTRICAL CONNECTION TO OPTIONAL CONTROLS987654321OLOCI1 4 72 5 83 6 9J3MAIN PC BOARDPUSH-BUTTON SWITCHES(HRV100H and HRV200H :5 swi

Pagina 12

2Table of Contents1. SERVICE ...

Pagina 13 - Figure 14

W R GYWRGCY987654321UNIT CONTROL CONNECTORTHERMOSTATTERMINALSFOUR WIRESI OC OL Y R G BF FJ3TWO WIRESheating onlyFURNACE24-VOLTTERMINAL BLOCKTWO WIR

Pagina 14 - Figure 15

COLOR CODEBK BLACK NC NO CONNECTIONBL BLUE O ORANGEBN BROWN R REDG GREEN W WHITEGY GREY Y YELLOW218. Wiring DiagramsA1M1M2K1RELAYK2RELAYK5RELAYFANMOTO

Pagina 15 - 6. Control Devices

22A1M1M2K1RELAYK2RELAYK5RELAYFANMOTORDAMPERMOTORNEUTRALMEDNCHIGHLOWJ1 6J1 3J1 4J1 9ELECTRONIC ASSEMBLYS1120V 60HzFROM MAINJ1 2J1 1J1 8VE0040ABKGRNO

Pagina 16 - 6. Control Devices (cont’d)

23WHAT YOU NEED TO BALANCE THE UNIT• A magnehelic gauge capable of measuring 0 to 0.25 inch of water (0 to 62.5 Pa) and 2 plastic tubes.• Two ”Flow Me

Pagina 17 - PLATINUM

24BALANCING PROCEDURE1. Set the unit to high speed.Make sure that the furnace blower is ON if the installation is in any way connected to the ductwor

Pagina 18 - (cont’d)

At its very start-up, the Platinumcontrol will perform a bootingsequence before being ready tooperate. The booting sequence isdone when the hour displ

Pagina 19 - AND VT2W

20/40/60-MINUTE PUSH-BUTTON TIMER:(Not available for HRV100H and HRV200Hmodels.)Activate the push-button. Within 2 seconds,push one time for 20 minute

Pagina 20

27Start-up troubleshooting:NOTE: Inspect the unit before proceeding with these steps.12. TroubleshootingPROBLEMS POSSIBLES CAUSES YOU SHOULD TRY THIS

Pagina 21 - 2001 HRV, ERV100HC, ERV200HC

13. ReferencesR 2000• HVI, “Installation Manual for Heat Recovery Ventilators”, 1987 edition.• ASHRAE 1984 Systems Handbook, chapter 11, “Air Distribu

Pagina 22 - Models: HRV100H, HRV200H

31.1 3-D DRAWING6123457891011121314151617181920212232323242526VL0016DAMPER ASSEMBLY (REAR VIEW)About this ManualThis manual uses the following symbols

Pagina 23 - 9. Air Flow Balancing

4Canada: Tel: 1-888-908-2633 (for distributors only)U.S.A.: Tel: 1-800-637-1453No. Description1001 1001 2001 2001 HRV ERV HRV ERVHRV ERV HRV ERV 100H

Pagina 24

ANCHORAGEWHITEHORSEJUNEAUHAY RIVERYELLOWKNIFEPrince RupertGRANDE PRAIRIEFORT MCMURRAYZONE AFORT SMITHEDMONTONPRINCE ALBERTSASKATOONJASPERKAMLOOPSCALGA

Pagina 25 - EXCHANGE

63.3 DEFROST CYCLE TABLE3.1 AIR DISTRIBUTION (NORMAL OPERATION)3.2 AIR DISTRIBUTION (DEFROST MODE)3. Technical DataVF0013FRESH AIRFROMOUTSIDESTALE AIR

Pagina 26 - 10.2 OPTIONAL CONTROLS

713¾" (349mm)20"(508mm)6" (152mm)2½" (63mm)30¼" (768mm)VK0040A19" (483mm)20"(508mm)6" (152mm)30¼" (768mm)

Pagina 27 - 12. Troubleshooting

84. Typical Installation(Primarily for homes with radiant hot water or electric baseboard heating. See figure 1.)Moist, stale air is exhausted from th

Pagina 28 - 12. Troubleshooting (cont’d)

95. InstallationChoose an appropriate location for the unit:• Within an area of the house where the temperature is kept above 10°C / 50°F and below 40

Commenti su questo manuale

Nessun commento